I11 - Imaginarni 11
Imaginarni 11
General Information
This European Standard specifies requirements for Guarantees of Origin of electricity from all energy sources and of gaseous
hydrocarbons, Hydrogen, and heating & cooling.
This standard will establish the relevant terminology and definitions, requirements for registration, issuing, transferring and
cancellation in line with the RED and Cogeneration.
This standard will specify how to create accounts and associated ownership rights.
This standard will also cover measuring methods and auditing procedures.
These Guarantees of Origin may be traded and/or used for Disclosure/Labelling.
This standard is suitable for certification purposes.
This standard will specify the requirements on the issuing bodies and on the auditing bodies.
- Standard82 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61847:2025 specifies:
– the essential non-thermal output characteristics of ultrasonic surgical units;
– methods of measurement of these output characteristics;
– those characteristics to be declared by the manufacturers of such equipment.
This document is applicable to equipment which meets the criteria of a), b) and c) below:
a) ultrasonic surgical systems operating in the frequency range 20 kHz to 120 kHz; and
b) ultrasonic surgical systems whose use is the fragmentation, emulsification, debridement, or cutting of human tissue, whether or not those effects are delivered in conjunction with tissue removal or coagulation; and
c) ultrasonic surgical systems in which an acoustic wave is conducted by means of a specifically designed wave guide to deliver energy to the surgical site.
This document is not applicable to:
– lithotripsy equipment which uses extracorporeally induced pressure pulses, focused through liquid conducting media and the soft tissues of the body;
– surgical systems used as part of the therapeutic process (hyperthermia systems);
– surgical systems whose mechanism of action is through frictional heat generated by tissue in contact with the wave guide, e.g. clamp coagulators or clamping vibrational cutters;
– surgical systems whose mechanism of action is through focused ultrasound for either thermal degradation (high intensity focused ultrasound – HIFU or HITU) or cavitation erosion (Histotripsy) of tissue remote from the ultrasound transducer;
– surgical systems whose mechanism of action is through erosion of hard tissues in contact with the applicator tip, e.g. bone cutting or drilling.
This document does not deal with the effectiveness or safety of ultrasonic surgical systems. This document does not deal with airborne noise from the systems, which can affect operators and patients.
IEC 61847:2025 cancels and replaces the first edition published in 1998. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) The upper frequency covered by this document has been raised from 60 kHz to 120 kHz.
b) The hydrophone method of measuring ultrasound power is now normative. Because of difficulties in using the calorimetry method of measuring ultrasound power, it is no longer the primary approach.
c) It is recognised that some systems can have more than one mode of vibration under user control, and the measurement techniques and declarations have been updated to address this.
d) The high-frequency component, which relates to cavitation developed at the applicator tip and the vibration amplitude at which cavitation occurs is addressed.
e) Specific requirements for measurement at excursion levels where no cavitation is present, and extrapolation to maximum excursion level(s) are described.
f) Guidance is provided to adapt the methodology described to more complex designs and vibration patterns, excursion directions, and their output characteristics.
g) Guidance is provided with respect to measurement tank arrangements for different types of systems.
h) The list of ultrasound methods and systems not covered by this document was extended to incorporate recent developments.
i) Definitions for cavitation related terms were added.
j) Requirements for the measurement of directivity characteristics of the applicator tip were changed.
k) Annex A was modified and Figure A.1 wa
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63378-3:2025 specifies the thermal circuit network model of discrete (TO‑243, TO‑252 and TO‑263) packages, which is used in the transient analysis of electronic devices to estimate precise junction temperatures without experimental verification.
This model is intended to be made and provided by semiconductor suppliers and to be used by assembly makers of electronic devices.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63171:2025 is the general requirements and general tests part (general specification) of the whole IEC 63171 series, a set of International Standards covering shielded or unshielded free and fixed connectors for balanced single-pair data transmission with current carrying capacity. It provides the signal integrity requirements, common to the whole series.
- Standard46 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
This NWI Will be a TS and will specify additional requirements for qualified or not qualified trust services implementing electronic archiving service with specific regard to :
• Functional requirements to use for receipt, storage, retrieval and deletion to ensure that the electronic data and electronic documents (electronically-born documents and paper documents that have been scanned and digitized) are preserved in such a way that they are accessible and durably safeguarded against loss and unauthorized alteration or disposal, except for authorized changes concerning their electronic format.
• Procedures and technologies ensuring the accuracy of the origin, the durability and legibility, integrity of the electronic data and electronic documents beyond the technological validity period and at least throughout the legal or contractual preservation period, while maintaining their integrity and their origin.
• Procedures and technologies to use to allow authorised relying parties to receive a report in an automated manner that confirms that an electronic data and electronic documents retrieved from a qualified electronic archive enjoys the presumption of integrity of the data and electronic documents from the beginning of the preservation period to the moment of retrieval.
• Procedures and technologies to prevent unauthorized access and improper use of the confidential and restricted data and electronic documents.
• Interactions between electronic archiving trust services and other trust services.
• Procedures and technologies to reach and obtain a green sustainability approach when possible.
- Technical specification36 pagesEnglish languagesale 10% offe-Library read for1 day
- Corrigendum4 pagesEnglish and French languagesale 10% offe-Library read for1 day
- Corrigendum3 pagesEnglish and French languagesale 10% offe-Library read for1 day
IEC 62276:2025 applies to the manufacture of synthetic quartz, lithium niobate (LN), lithium tantalate (LT), lithium tetraborate (LBO), and lanthanum gallium silicate (LGS) single crystal wafers intended for use as substrates in the manufacture of surface acoustic wave (SAW) filters and resonators.
This edition includes the following significant technical changes with respect to the previous edition:
a) The terms and definitions, the technical requirements, sampling frequency, test methods and measurement of transmittance, lightness, colour difference for LN and LT have been added in order to meet the needs of industry development;
b) The term “inclusion” (mentioned in 4.13 and 6.10) and its definition have been added because there was no definition for it in Clause 3;
c) The specification of LTV and PLTV, and the corresponding description of sampling frequency for LN and LT have been added, because they are the key performance parameters for the wafers;
d) The tolerance of Curie temperature specification for LN and LT have been added in order to meet the development requirements of the industry;
e) Measurement of thickness, TV5, TTV, LTV and PLTV have been completed, including measurement principle and method of thickness, TV5, TTV, LTV and PLTV.
- Standard44 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies test methods for cable management systems (CMS) intended to provide support for intrinsic fire-resistant cables in order to determine their abilities to maintain the function of electrical power cables and signal/control cables for a specified duration when subjected to fire under defined conditions.
This document establishes a non-hierarchical classification for this ability.
Additional devices to fix the cable management systems providing fire resistant support (CMS-support) to the building structure for example screws, anchors etc. are not covered by this document.
CMS intended to provide support and fire protection for cables are tested according to EN 1366-11.
This document does not apply to powertrack systems.
NOTE Rules for testing CMS-support for fibre optic cables according to EN 50582 and communication cables according to EN 50289-4-16 are under consideration.
- Technical specification53 pagesEnglish languagesale 10% offe-Library read for1 day
This document provides design-for-recycling guidelines for Polyvinyl Chloride (PVC) cable management products and recommends design options to ensure the product is recyclable.
This document is limited to the recycling of PVC cable management products.
NOTE 1 The following PVC containing products are considered as examples:
- Conduits and fittings;
- Liquid tight sheathing and fittings;
- Cable trunking and cable ducting lengths and other system components;
- Cable tray and cable ladder lengths and other system components;
- Cable cleats;
- Cable glands;
- Cable ties;
- Cover plates and cover tapes;
- Articulated and flexible system components.
Products associated with or incorporated in a PVC cable management system component but which are not system components (e.g. enclosures, connecting boxes) are not within the scope of this document.
NOTE 2 Cable management products are generally subject to European Standards specifying requirements and tests to ensure adequate safety and appropriate performance.
NOTE 3 Packaging of cable management products is not covered by this document.
- Technical specification10 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60404-18:2025 defines the general principle and technical details of the methods of measurement of the DC magnetic properties of permanent magnet materials in an open magnetic circuit using a superconducting magnet (SCM).
This method is applicable to permanent magnet materials, such as those specified in IEC 60404‑8‑1, the properties of which are presumed homogeneous throughout their volume.
There are two methods:
- the SCM-vibrating sample magnetometer (VSM) method;
- the SCM-extraction method.
This document also specifies methods to correct the influence of the self-demagnetizing field in the test specimen on the demagnetization curve obtained in an open magnetic circuit. The magnetic properties are determined from the corrected demagnetization curve.
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62933-4-2:2025 defines the requirements for evaluating and reporting the negative impact on the environment caused by the failure of a cell, flow cell, battery or flow battery in the accumulation subsystem of a battery energy storage system (BESS).
The batteries within this scope used in a BESS are classified according to the type of their electrolyte. These electrolyte types are aqueous, non-aqueous or solid.
The environmental impacts directly caused by the failure of other components of the BESS are not within the scope of this document.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62391-2:2025 applies to electric double-layer capacitors for power application.
Electric double-layer capacitors for power are intended for applications that require discharge currents in the range from mA to A. The characteristics of the capacitors include such performance as relatively high capacitance and low internal resistance, which is applicable to Class 3 and Class 5 of the measurement classification specified in IEC 62391-1:2022.
The object of this document is to specify preferred ratings and characteristics and to select from IEC 62391-1:2022 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this document provide specific test severities and requirements of an equal or higher performance level.
The definition of power density and its calculating procedure can be found in Annex A.
This edition includes the following significant technical changes with respect to the previous edition:
a) the document has been completely restructured to comply with the ISO/IEC Directives, Part 2;
b) introduction of a new technical categorization for the test methods;
c) reorganization of the test methods have been according to these new categories;
d) revision of the tables, figures and references according to changes.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61846:2025 is applicable to:
– therapy equipment using extracorporeally induced focused pressure pulse waves;
– therapy equipment producing focused mechanical energy excluding thermal energy.
This document does not apply to percutaneous and laser lithotripsy equipment.
This document does not apply to:
– histotripsy or other therapeutic ultrasound bursts of longer time duration than that of the pressure pulse;
– non-focused pressure pulse equipment.
This document specifies:
– measurable parameters which could be used in the declaration of the acoustic output of extracorporeal focused pressure pulse equipment;
– methods of measurement and characterization of the pressure field generated by focused pressure pulse equipment.
While this document has been developed for equipment intended for use in lithotripsy, it has been developed such that, as long as no other specific standards are available to be used for other medical applications of therapeutic extracorporeal focused pressure pulse equipment, this document can be used as a guideline.
IEC 61846:2025 cancels and replaces the first edition published in 1998. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Change of title: "pressure pulse lithotripters" in the previous edition is changed to "therapeutic focused short pressure pulse sources" in order to take into account the development in the relevant technical and biomedical applications of such sources, which were originally used only for (kidney) lithotripsy, while recent applications include a wide range for the treatment of, for example, stone diseases, orthopaedic pain, tissue, cardiac and brain diseases.
The term "focused" was added to differentiate IEC 61846 from IEC 63045.
The term "short" was added to align the nomenclature to IEC 63045 and to differentiate IEC 61846 from standards in the HIFU and HITU fields.
b) Clause 1 and elsewhere in the document: The term "lithotripsy" is changed to "therapy" in order to account for the wide range of applications beyond stone diseases.
c) Clause 3: The "−6 dB" parameter definitions are replaced by "−n dB" to avoid misconceptions in the significance and use of these parameters and to account for newer findings in literature.
Additional "n MPa" parameters are introduced for the same reasons.
The definitions of "derived" parameters are aligned to those in recently published standards, for example IEC 62127-1.
New definitions were added which describe parameters appearing in newer relevant literature, for example "momentum", "average positive acoustic pressure", "cavitation induction index", "pulse to pulse variability", "total pressure pulse energy dose".
d) Clause 6: The terms "focus hydrophone" and "field hydrophone" were removed to account for newer technical developments. New terms distinguish between "hydrophones for pressure pulse measurements" and "hydrophones for quality assurance".
e) Annexes: Descriptions, tables and figures were edited to account for newer literature and standards as well as technical developments.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62813:2025 specifies the electrical characteristics (capacitance, internal resistance, discharge accumulated electric energy, and voltage maintenance rate) test methods of lithium-ion capacitors (LIC) for use in electric and electronic equipment.
This edition includes the following significant technical changes with respect to the previous edition:
a) The document has been restructured to comply with the ISO/IEC Directives, Part 2.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62127-2:2025 specifies:
- absolute hydrophone calibration methods;
- relative (comparative) hydrophone calibration methods.
Recommendations and references to accepted literature are made for the various relative and absolute calibration methods in the frequency range covered by this document.
This document is applicable to
- hydrophones used for measurements made in water and in the ultrasonic frequency range 50 kHz to 100 MHz;
- hydrophones employing piezoelectric sensor elements, designed to measure the pulsed wave and continuous wave ultrasonic fields generated by ultrasonic equipment;
- hydrophones with or without a hydrophone pre-amplifier.
IEC 62127-2:2025 cancels and replaces the first edition published in 2007, Amendment 1:2013 and Amendment 2:2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the upper frequency limit of 40 MHz has been removed;
b) hydrophone sensitivity definitions have been changed to recognize sensitivities as complex-valued quantities;
c) directional response measurement and effective size determination procedures have been updated in 12.5.1 to align with recent changes in IEC 62127-3;
d) Annex F has been amended to comprise a calibration technique for high-frequency complex-valued calibration;
e) the reciprocity method description in Annex K was extended to also comprise focusing transducers.
- Standard117 pagesEnglish languagesale 10% offe-Library read for1 day
This document provides the guidelines of CEN and CENELEC’s policy towards building partnerships with
European organizations, associations and other recognized stakeholders who have an interest in European
standardization and are willing and able to provide added-value knowledge and to actively contribute with
inputs and proposals to CEN and/or CENELEC corporate and technical bodies.
- Guide18 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62309:2024 introduces the concept to check the reliability and functionality of reused parts and their usage within new products. It also provides information and criteria about the assurance [for example, testing and analysis, required for products containing reused parts, which are declared "qualified-as-good-as-new" (QAGAN)] relative to the designed life of the product.
This document specifies requirements to be satisfied before making a declaration or applying a designation of QAGAN. This document also gives guidance to support any organisation that makes declarations about dependability of products containing reused parts.
In this document, the term "product" covers electrical, electro-mechanical, mechanical parts or hardware that can contain software.
"Qualified-as-good-as-new" (QAGAN) does not apply to reused materials or large structures and large systems, nor does it cover software products, concepts, and ideas.
The purpose of this document is to ensure by tests and analysis that the reliability and functionality of a new product containing reused parts is comparable to a product that contains only new parts. This would justify the manufacturer granting the next customer the full warranty of the product with "qualified-as-good-as-new" (QAGAN) parts.
Annex A describes extending useful life by refurbishment, updating, upgrading, maintenance and used as second-hand. These concepts are defined and the requirements for using the term with reference to this document are stated.
This second edition cancels and replaces the first edition published in 2004. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the previous Annex A has been separated into Annex B (Dependability aspects) and Annex C (Example with QAGAN parts);
b) a new normative Annex A has been written with expansion of lifecycle activities, to describe extending the useful life by refurbishment, life extension, updating, upgrading and second-hand use;
c) revision of Figure 1 accordingly;
d) minor editorial alignments throughout the document;
e) the abbreviation "quagan" has been changed "QAGAN" to reflect more contemporary use.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61076-2-101:2024 describes M12 screw-locking circular connectors with 2-way up to 17‑way, for data transmission with frequencies up to 100 MHz and signal and power transmission at up to 250 V rated voltage and up to 4 A rated current per contact.
These connectors consist of fixed and free connectors, either rewirable or non-rewirable.
Male connectors have round contacts, Ø 0,6 mm, Ø 0,76 mm, Ø 0,8 mm or Ø 1,0 mm according to number of ways and coding, all contacts with the same size.
The different codings prevent the mating of differently coded male and female connectors.
This fourth edition cancels and replaces the third edition published in 2012. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Technical specifications regarding dimensional information (Clause 5) and characteristics (Clause 6) have been updated, and new subclauses have been added.
b) New style NF (free connectors) has been added.
c) Fixed connectors with glass to metal seals (former styles WM, XM, YM, ZM and WF, XF, TF and ZF) are no longer covered by this document: relevant definitions and requirements have been removed.
d) The P-coding has been eliminated.
e) Annex B (informative) Steel conduit thread, sizes has been deleted and a new Annex B (informative) Orientation of cable outlet in relation to coding has been added.
f) The dimension specification of former styles AM and BM have been moved into a new Annex C (normative).
- Standard77 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60352-2:2024 is applicable to solderless crimped connections made with:
- appropriately designed uninsulated or pre-insulated crimp barrels as parts of crimp contacts, terminal ends or splices, and
- stranded wires of 0,05 mm2 to 10 mm2 cross-section or
- solid wires of 0,25 mm to 3,6 mm diameter;
for use in electrical and electronic equipment.
Information on the materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions.
This part of IEC 60352 is not applicable to crimping of coaxial cables.
This part of IEC 60352 determines the suitability of solderless crimped connections as described above, under specified mechanical, electrical and atmospheric conditions and provides a means of comparing test results when the tools used to make the connections are of different designs or manufacture.
- Standard134 pagesEnglish languagesale 10% offe-Library read for1 day
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60747-16-9:2024 specifies the terminology, essential ratings, and characteristics, and measuring methods of microwave integrated circuit phase shifters.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the reference architecture for a hyperloop system. It specifies the functions of each (sub)system classifying them in different functional blocks, their different possible implementations, and highlights the interactions between them.
The interfaces of the transportation system based on interactions are listed, whether it be internal interfaces or exterior interfaces. The characterization considers the technical as well as operational features of the transport service.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60747-15:2024 gives the requirements for isolated power semiconductor devices. These requirements are additional to those given in other parts of IEC 60747 for the corresponding non-isolated power devices and parts of IEC 60748 for ICs. This third edition includes the following significant technical changes with respect to the previous edition:
a) The intelligent power semiconductor modules (IPM), which was previously excluded from the first and second edition, is now included in this document (Annex C);
b) The thermal resistance is described for each switch (6.2.4);
c) Added isolation test between temperature sensor and terminals, in case there is an agreement with the user (6.1.2).
- Standard61 pagesEnglish languagesale 10% offe-Library read for1 day
This document proposes a method to achieve circular designs of products. It details principles, requirements and guidance associated with the proposed method. This document:
• specifies requirements and guidance for integrating circularity into the design and development process of products by an organization and,
• supports organizations to develop product design rules to fulfil their chosen circular business targets (e.g. the circular business models chosen by the organization or the legislation requirements).
Having life cycle thinking as a core principle, this document provides guidance on how to reduce environmental impacts, and how to deal with challenges such as trade-offs during circular product design, without compromising other product functions including safety.
This document focusses on material efficiency. It is not a management system standard.
This document can be applied when no product-specific or product group standard exist. Where such documents are developed, this document can be used as reference to ensure consistency and harmonization across the different product areas and supply chains or networks.
NOTE For the purpose of this document, the following products are excluded: food, feed, medicinal products for human use, veterinary medicinal products, living plants, animals and microorganisms, products of human origin, products of plants and animals relating directly to their future reproduction.
- Standard59 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60512-28-100:2024 specifies the test methods for signal integrity and transmission performance for connectors specified in respective parts of IEC 60603-7, IEC61076-1, IEC 61076-2, IEC 61076-3 and IEC 63171 series of standards for connecting hardware applications from 0,1 MHz up to 2 000 MHz, with reference to this document.
Note: This document is also suitable for testing signal integrity and transmission performance of connectors up to a lower value of maximum frequency; however, the test methodology specified in the detail specification for any given connector remains the reference conformance test for that connector.
The list of connector series of standards does not preclude referencing this document in other connector manufacturer’s specifications or published standards.
Test procedures provided herein are:
- insertion loss, test 28a;
- return loss, test 28b;
- near-end crosstalk (NEXT) test 28c;
- far-end crosstalk (FEXT), test 28d;
- transverse conversion loss (TCL), test 28f;
- transverse conversion transfer loss (TCTL), test 28g.
Other test procedures referenced herein are:
- shield transfer impedance (ZT), see IEC 60512‑26‑100, test 26e.
- coupling attenuation (aC), see IEC 62153-4-7 and IEC 62153‑4‑12.
- low frequency coupling attenuation (aCLF) see IEC 62153-4-7 and IEC 62153-4-15
This edition includes the following significant technical changes with respect to the previous edition:
-The frequency range has been modified to start at 0,1 MHz instead of 1 MHz, to include single-pair connectors.
-All tables and requirements have been revised down to 0,1 MHz, and partially improved to reduce the impact of the test fixture.
-Formulae to calculate the S-parameters from single-ended parameters have been added.
-A note was added for those parameters which are not applicable to single-pair connectors.
- Standard52 pagesEnglish languagesale 10% offe-Library read for1 day
- Corrigendum7 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60300-3-14:2024 introduces the dependability attribute of supportability (and support) and the relationship with related dependability attributes of reliability, maintainability and availability.
This document can be used at any time during an item’s life to guide the planning and implementing of supportability and support activities focused on achieving an intended balance of performance, cost and risk. All activities can be tailored to the nature of the item and its conditions of use.
Guidance is offered on how supportability and support activities can be applied at any life cycle stage for newly designed items, existing items available for commercial procurement, or for items during their operational life.
This document considers the life cycle implications by formally managing risks associated with the management and delivery of activities to create, operate, maintain and refurbish an item to achieve its stated purpose.
This document describes the:
- nature of supportability and support;
- role of supportability and support in achieving item value over its life;
- trade-offs associated with supportability and support to achieve desired balance of cost, performance and risk during the life of an item;
- importance of aligning the structure of an organization with its objectives, with the ultimate aim of improving efficiency and effectiveness in order to deliver the required supportability and support.
This second edition cancels and replaces the first edition published in 2004. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) consistency with the other core dependability standards prepared by IEC TC 56;
b) expansion of supportability and support principles and activities in dependability.
- Standard60 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-9:2024 is available as IEC 60384-9:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60384-9:2024 is applicable to fixed capacitors of ceramic dielectric with a defined temperature coefficient (dielectric Class 2), intended for use in electronic equipment, including leadless capacitors but excluding fixed surface mount multilayer capacitors of ceramic dielectric, which are covered by IEC 60384-22 (Class 2). Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. The object of this document is to specify preferred ratings and characteristics and to select from IEC 60384-1:2021 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this document provide specific test severities and requirements of an equal or higher performance level. Further information on the conception of generic, sectional and detail specifications can be found in the Introduction of IEC 60384-1:2021.
This edition includes the following significant technical changes with respect to the previous edition:
a) The document has been completely restructured to comply with ISO/IEC Directives, Part 2 and to make it more useable; tables, figures and references have been revised accordingly. Annex X contains all cross-references of changes in clause/subclause numbers.
b) The requirements of reference temperature 25 °C have been added in Table 7, Table 9, Table 11, Table 13 and Table 15.
c) The table of temperature characteristics of capacitance for the reference temperature 25 °C have been added in Table B.1, Table B.2 and Table B.3.
d) Annex B has been changed from informative to normative.
e) Clause C.5 (Test schedule for quality conformance inspection) has been newly added to withdraw the blank detail specification: IEC 60384-9-1.
- Standard48 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-8:2024 is available as IEC 60384-8:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60384-8:2024 is applicable to fixed capacitors of ceramic dielectric with a defined temperature coefficient (dielectric Class 1), intended for use in electronic equipment, including leadless capacitors but excluding fixed surface mount multilayer capacitors of ceramic dielectric, which are covered by IEC 60384-21 (Class 1). Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. The object of this document is to specify preferred ratings and characteristics and to select from IEC 60384-1:2021, the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this document provide specific test severities and requirements of an equal or higher performance level. Further information on the conception of generic, sectional and detail specifications can be found in the Introduction of IEC 60384-1:2021.
This edition includes the following significant technical changes with respect to the previous edition:
a) The document has been completely restructured to comply with ISO/IEC Directives, Part 2 and to make it more useable; tables, figures and references have been revised accordingly. Annex X contains all cross-references of changes in clause/subclause numbers.
b) The terms have been replaced by the letter symbols in Table 3.
c) Code of temperature coefficient and tolerance of C0G, U2J have been added in Table 4, Table 6, Table 8, Table 9, Table 11, Table 13, Table 16 and Annex B.
d) Annex B has been changed from informative to normative.
e) Clause C.5 (Test schedule for quality conformance inspection) has been newly added to withdraw the blank detail specification: IEC 60384-8-1.
- Standard55 pagesEnglish languagesale 10% offe-Library read for1 day
This part 2-3 of the EN IEC 61084 series specifies particular requirements and tests slotted cable
trunking systems intended for mounting inside cabinets in electrical and/or communication system installations.
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
Common modifications for the adoption as a European Standard of IEC 61084-2-3:2017 ed 1.0 (PR=72102)
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
Common modifications for the adoption as a European Standard of IEC 61084-1:2017 ed 2.0 (PR= 69866).
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
This part 2-2 of the EN IEC 61084 series specifies particular requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for mounting underfloor, flushfloor or onfloor.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
Common modifications for the adoption as a European Standard of IEC 61084-2-4:2017 ed 2.0 (PR=72103)
- Amendment9 pagesEnglish languagesale 10% offe-Library read for1 day
Common modifications for the adoption as a European Standard of IEC 61084-2-1:2017 ed 2.0 (PR=72100)
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62933-5-1:2024 specifies safety considerations (e.g. hazards identification, risk assessment, risk mitigation) applicable to EES systems integrated with the electrical grid. This document provides criteria to enable the safe application and use of electrical energy storage systems of any type or size intended for grid-integrated applications. This document can be applied to all EESS technologies, but for requirements specific to electrochemical EES systems, reference is also made to IEC 62933-5-2. This first edition cancels and replaces the first edition of IEC TS 62933-5-1 published in 2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to IEC TS 62933‑5‑1:2017:
a) Revising “should” statements to “shall” statements for all requirements and move some “should” statements clauses to Annex B for informative purposes.
b) Update standard references (normative).
c) Update definitions and add or remove definitions where necessary.
d) Revise criteria in Clause 6 and Clause 7 to be actionable and add standard references where necessary.
e) Revise Clause 8 for more thorough test method and criteria, add tests where necessary.
f) Add markings and instruction criteria.
g) Revise Annex A to add technology safety information on gravitational and thermal EESS.
h) Add Annex B and Annex C for safety considerations for EESS and test method for mechanical EESS.
i) Add informative list of standards and update bibliography.
- Standard89 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
This part 1 of the EN IEC 61084 series specifies general requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V AC and 1 500 V DC.
- Standard47 pagesEnglish languagesale 10% offe-Library read for1 day
Common modifications for the adoption as a European Standard of IEC 61084-2-2:2017 ed 2.0 (PR= 72101).
- Amendment10 pagesEnglish languagesale 10% offe-Library read for1 day
This part 2-4 of the EN IEC 61084 series specifies particular requirements and tests for service poles and service posts intended to be mounted in free space and in contact with mounting surface(s) only at one or two ends, where the word "mounted" means fixed or placed on the floor with a weighted base or linked to a mounting surface through a flexible component.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This part 2-1 of the EN IEC 61084 series specifies particular requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for intended for mounting on walls and ceilings. They can be embedded, installed in a flush or semi-flush state, surface mounted or mounted away from the surface using fixing devices.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63412-1:2024 specifies quantities and parameters which it is essential to provide to the user of shear-wave elastography systems, many in the image headers.
This document is applicable to medical-diagnostic, ultrasonic shear-wave elastography systems, exciting (internally or externally) shear waves and tracking their propagation within biological tissue.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60300-1:2024 provides guidance on:
- the meaning and significance of dependability from a business, technical and financial perspective;
- achieving dependability through suitable adaptation of organizational management systems such as those described in ISO 9001 (quality management) and ISO 55001 (asset management);
- the activities that are integrated into management systems and life cycle processes in order to achieve dependable systems, products and services;
- planning and implementing dependability activities throughout the life cycle to achieve and assure required outcomes, taking into account factors such as costs, safety, the environment, customer goodwill, brand and reputation.
This document is applicable to any type of system, both new and existing, to mass produced industrial or consumer products, to components and to services. This document addresses all elements of systems, products and services including hardware, software, data, processes, procedures, facilities, materials, and personnel required for operations and support.
- Standard75 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-22:2024 is applicable to fixed unencapsulated surface mount multilayer capacitors of ceramic dielectric, Class 2, for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted on printed boards, or directly onto substrates for hybrid circuits.
Capacitors for electromagnetic interference suppression are not included but are covered by IEC 60384-14. The object of this document is to specify preferred ratings and characteristics and to select from IEC 60384-1:2021 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification provide specific test severities and requirements of an equal or higher performance level. Further information on the conception of generic, sectional and detail specifications can be found in the Introduction of IEC 60384-1:2021.
This edition includes the following significant technical changes with respect to the previous edition:
a) The document has been completely restructured to comply with the ISO/IEC Directives, Part 2 and to make it more useable; tables, figures and references have been revised accordingly.
b) The requirements of reference temperature 25 °C has been added in Table 5, Table 9, Table 10, Table 12, Table 14 and Table 17.
c) The table of temperature characteristics of capacitance for the reference temperature 25 °C have been added in Table C.1, Table C.2 and Table C.3.
d) The requirement in 5.5.2 (visual examination) has been repeated in 5.9.3, 5.10.6, 5.11.4, 5.12.6, 5.13.8, 5.14.6 and 5.15.6.
e) The deflection D in the very robust designs has been added in 5.9.1.
f) Annex C has been changed informative into normative.
g) Clause D.5 (Test schedule for quality conformance inspection) has been newly added to withdraw the blank detail specification: IEC 60384-22-1.
- Standard55 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-21:2024 is applicable to fixed unencapsulated surface mount multilayer capacitors of ceramic dielectric with a defined temperature coefficient (dielectric Class 1), intended for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted on printed boards, or directly onto substrates for hybrid circuits. Capacitors for electromagnetic interference suppression are not included but are covered by IEC 60384-14. The object of this document is to specify preferred ratings and characteristics and to select from IEC 60384-1:2021 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification provide specific test severities and requirements of an equal or higher performance level. Further information on the conception of generic, sectional and detail specifications can be found in the Introduction of IEC 60384-1:2021.
This edition includes the following significant technical changes with respect to the previous edition:
a) the document has been completely restructured to comply with the ISO/IEC Directives, Part 2 and to make it more useable; tables, figures and references have been revised accordingly; Annex X contains all cross-references of changes in clause/subclause numbers;
b) the terms have been replaced by the letter symbols in Table 3;
c) code of temperature coefficient and tolerance of C0G, U2J have been added in Table 4, Table 6, Table 8, Table 9, Table 11, Table 13, Table 16 and Annex B;
d) the requirement in 5.5.2(visual examination) has been repeated in 5.9.3, 5.10.5, 5.11.4, 5.11.4, 5.13.7, 5.14.5 and 5.15.5;
e) the deflection D in the very robust designs has been added in 5.9.1;
f) Annex B has been changed informative into normative;
g) Clause C.5 (Test schedule for quality conformance inspection) has been newly added to withdraw the blank detail specification: IEC 60384-21-1.
- Standard48 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62933-1:2024 defines terms applicable to electrical energy storage (EES) systems including terms necessary for the definition of unit parameters, test methods, planning, installation, operation, environmental and safety issues.
This terminology document is applicable to grid-connected systems able to extract electrical energy from an electric power system, store energy internally, and provide electrical energy to an electric power system. The step for charging and discharging an EES system can comprise an energy conversion.
This second edition cancels and replaces the first edition published in 2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) addition (with revision) of the entries developed during the edition 1 stability period and, therefore, included only in other IEC 62933 parts;
b) addition of the entries developed during the edition 1 stability period and published in this document for the first time;
c) complete revision of the entries already present in edition 1.
- Standard55 pagesEnglish languagesale 10% offe-Library read for1 day